1. Industries
  2. Manufacturing industry
  3. Defense infrastructure
  4. SCIFs

Further sealing solutions for your SCIFs

Roxtec cable and pipe transits ensure electromagnetic shielding both inside and around the SCIF rooms. Use Roxtec EMC solutions to protect equipment and create an internal barrier for sensitive information. Stop RFI, optimize communication security and ensure safety.

Why use Roxtec?

  • Watertight
  • Dust-tight
  • EMI/EMP protection
  • Area efficient
  • Blast load protection
  • Shock-wave resistant
  • Firestop

Superior simplicity

  • Easy and safe installation
  • Built-in spare capacity for upgrades and retrofits
  • Lightweight
  • Flexibility for cables and pipes of different sizes
  • EMC solutions for electrical safety
  • Ex solutions for hazardous locations
Roxtec GH EMC transit

Roxtec GH EMC transit

fire rated.svg
ip-ul nema.svg
emi protection.svg
gas-tight.svg

Transit for EMC, for bolting to even structures.

For bolting to steel or sandwich walls in EMC applications

Fire

  • E/EI rating according to EN 13501

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67 according to IEC 60529
  • IP 68

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec G bolted Ex transit

Roxtec G bolted Ex transit

ip-ul nema.svg
ex rated.svg
emi protection.svg
electrical saftey.svg
fire rated.svg

Ex rated transit with flange, for bolting.

For bolting to enclosures

Fire

  • E/EI rating according to EN 13501

Tightness

  • IP 66/67 according to IEC 60529

Supports

  • Bonding and grounding
  • Electromagnetic shielding
  • Potential equalization
  • Ex rated
Roxtec B Ex transit

Roxtec B Ex transit

fire rated.svg
ip-ul nema.svg
ex rated.svg
emi protection.svg

Ex rated transit with flexible frame enabling combinations.

For retrofit when casting in hazardous locations

Fire

  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479

Tightness

  • IP 54 according to IEC 60529

Supports

  • Potential equalization
  • Ex rated
Roxtec RS seal with SLFO/RI

Roxtec RS seal with SLFO/RI

fire rated.svg
watertight.svg
gas-tight.svg

Penetration seal for a single cable or pipe.

Includes openable sleeve for installation around existing cables/pipes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 1 bar (catastrophic)
  • Water: 2 bar (catastrophic)
Roxtec RS Ex seal with SLF RS

Roxtec RS Ex seal with SLF RS

fire rated.svg
watertight.svg
gas-tight.svg
ex rated.svg
ip-ul nema.svg

Ex rated seal for bolting, for a single cable or pipe.

Includes sleeve for bolting in hazardous locations

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68
  • UL/NEMA 4,4X,12,13

Supports

  • Ex rated
Roxtec R transit with SLFO/RI

Roxtec R transit with SLFO/RI

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg
ip-ul nema.svg

Openable transit for sealing around existing cables/pipes.

Includes openable sleeve for installation around existing cables/pipes

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 1 bar (catastrophic)
  • Water: 2 bar (catastrophic)
  • IP 68

Supports

  • Potential equalization
  • Electromagnetic shielding
Roxtec R EMC transit

Roxtec R EMC transit

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg
ip-ul nema.svg

Round transit for EMC, for area efficient sealing of multiple cables and pipes.

For use in existing sleeves in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec R Ex transit with SL R

Roxtec R Ex transit with SL R

fire rated.svg
watertight.svg
gas-tight.svg
ex rated.svg

Ex rated round transit for welding when sealing multiple cables and pipes in a limited area.

Includes sleeve for welding in hazardous locations

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Ex rated
Roxtec R Ex transit with SLF R

Roxtec R Ex transit with SLF R

fire rated.svg
watertight.svg
gas-tight.svg
ex rated.svg
ip-ul nema.svg

Ex rated round transit for bolting when sealing multiple cables and pipes in a limited area.

Includes sleeve for bolting in hazardous locations

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 66/67 according to IEC 60529

Supports

  • Ex rated