Use the print button on the page for an optimized print layout.

Roxtec RM modules are 60 mm (2.362") deep and easy to adapt to cable and pipes of different sizes. When used with a solid core, the module functions as a spare module for future capacity.

  • To be used with corresponding Roxtec components to form a complete sealing solution
  • For cables and pipes 3.0-99.0mm (0.118"-3.898") OD

Select your market to see available purchase options.

RM 30
RM 30
RM 20w40
RM 20w40
RM 60
RM 60
RM 80 WOC
RM 80 WOC
RM 30
RM 20w40
RM 60
RM 80 WOC

Certificates
Certifying authority Rating Division / Structure Cable Pipe Type approval name
BV A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Other Marine ABS Copper Copper-Nickel Fiberglass PB PE Plastic PP PVC PVDF Steel 73351/A1 BV
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Other Marine Copper Fiberglass PB PE PE/ALU/PE Plastic PP PVC Steel LR2386976SF
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Other Marine Copper Fiberglass PB PE PE/ALU/PE Plastic PP PVC Steel LR2387043MB
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) GRP/FRP Marine LR2543793UKMB
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) GRP/FRP Copper Fiberglass PE/ALU/PE Plastic Steel Titanium LR2543794UKMB
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) GRP/FRP Marine LR2543795UKMB
LR A class fire Gas tightness (catastrophic) Water tightness (catastrophic) GRP/FRP Copper Fiberglass PE/ALU/PE Plastic Steel Titanium LR2543796UKMB
ClassNK A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Aluminium Steel Bundle Copper Copper-Nickel Fiberglass Other Plastic Steel Titanium TA26927E(R)
DNV A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Other Marine TAF00001SH
DNV A class fire Gas tightness (catastrophic) Water tightness (catastrophic) Other ABS Copper Fiberglass HDPE Other PB PE PE/ALU/PE Plastic PP PVC PVDF Steel TAF00001SJ

Variants

RM 15

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 3 - 11
  • External dimensions WxHxD (mm) 15 x 15 x 60
  • Weight (kg) 0.02
  • Art. No RM00100151000

RM 15w40

  • Number of cables/pipes 3
  • For cable/pipe Ø (mm) 3.5 - 10.5
  • External dimensions WxHxD (mm) 40 x 15 x 60
  • Weight (kg) 0.05
  • Art. No RM00115401000

RM 20

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 4 - 14.5
  • External dimensions WxHxD (mm) 20 x 20 x 60
  • Weight (kg) 0.04
  • Art. No RM00100201000

RM 20w40

  • Number of cables/pipes 2
  • For cable/pipe Ø (mm) 3.5 - 16.5
  • External dimensions WxHxD (mm) 40 x 20 x 60
  • Weight (kg) 0.07
  • Art. No RM00120401000

RM 30

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 10 - 25
  • External dimensions WxHxD (mm) 30 x 30 x 60
  • Weight (kg) 0.08
  • Art. No RM00100301000

RM 40

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 21.5 - 34.5
  • External dimensions WxHxD (mm) 40 x 40 x 60
  • Weight (kg) 0.14
  • Art. No RM00100401000

RM 40 10-32

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 9.5 - 32.5
  • External dimensions WxHxD (mm) 40 x 40 x 60
  • Weight (kg) 0.14
  • Art. No RM00140101000

RM 40H80

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 21.5 - 34.5
  • External dimensions WxHxD (mm) 40 x 80 x 60
  • Weight (kg) 0.28
  • Art. No 165313

RM 60

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 28 - 54
  • External dimensions WxHxD (mm) 60 x 60 x 60
  • Weight (kg) 0.32
  • Art. No RM00100601000

RM 60 24-54

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 24 - 54
  • External dimensions WxHxD (mm) 60 x 60 x 60
  • Weight (kg) 0.33
  • Art. No RM00160201000

RM 80

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 48 - 71
  • External dimensions WxHxD (mm) 80 x 80 x 60
  • Weight (kg) 0.56
  • Art. No 5RM0000003350

RM 60 WOC

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 28 - 54
  • External dimensions WxHxD (mm) 60 x 60 x 60
  • Weight (kg) 0.26
  • Art. No RM00000601000

RM 80 WOC

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 48 - 71
  • External dimensions WxHxD (mm) 80 x 80 x 60
  • Weight (kg) 0.4
  • Art. No 5RM0000000534

RM 120 WOC

  • Number of cables/pipes 1
  • For cable/pipe Ø (mm) 67.5 - 99
  • External dimensions WxHxD (mm) 120 x 120 x 60
  • Weight (kg) 0.94
  • Art. No RM00001201000

SPLIT CORE KIT AISI316 FOR RM 120

  • Weight (kg) 0.47
  • Art. No 247070

SPLIT CORE KIT GALV FOR RM 120

  • Weight (kg) 0.47
  • Art. No 247071
Name Number of cables/pipes For cable/pipe Ø (mm) External dimensions WxHxD (mm) Weight (kg) Art. No
RM 15 1 3 - 11 15 x 15 x 60 0.02 RM00100151000
RM 15w40 3 3.5 - 10.5 40 x 15 x 60 0.05 RM00115401000
RM 20 1 4 - 14.5 20 x 20 x 60 0.04 RM00100201000
RM 20w40 2 3.5 - 16.5 40 x 20 x 60 0.07 RM00120401000
RM 30 1 10 - 25 30 x 30 x 60 0.08 RM00100301000
RM 40 1 21.5 - 34.5 40 x 40 x 60 0.14 RM00100401000
RM 40 10-32 1 9.5 - 32.5 40 x 40 x 60 0.14 RM00140101000
RM 40H80 1 21.5 - 34.5 40 x 80 x 60 0.28 165313
RM 60 1 28 - 54 60 x 60 x 60 0.32 RM00100601000
RM 60 24-54 1 24 - 54 60 x 60 x 60 0.33 RM00160201000
RM 80 1 48 - 71 80 x 80 x 60 0.56 5RM0000003350
RM 60 WOC 1 28 - 54 60 x 60 x 60 0.26 RM00000601000
RM 80 WOC 1 48 - 71 80 x 80 x 60 0.4 5RM0000000534
RM 120 WOC 1 67.5 - 99 120 x 120 x 60 0.94 RM00001201000
SPLIT CORE KIT AISI316 FOR RM 120 0.47 247070
SPLIT CORE KIT GALV FOR RM 120 0.47 247071