1. Industries
  2. Manufacturing industry
  3. Defense equipment
  4. Radar systems

Further sealing solutions for your radar systems

Roxtec sealing solutions for surveillance radar systems protect high-value radar electronics from electromagnetic interference and harsh outdoor conditions.They secure complex cable, fiber, and waveguide interfaces while preserving signal integrity and long-term system stability.

Why use Roxtec?

  • EMI/EMP protection
  • Dust-tight
  • Area efficient
  • Firestop
  • Watertight

Superior simplicity

  • EMC solutions for electrical safety
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for upgrades and retrofits
  • Customized solutions for specific requirements
Roxtec S EMC transit

Roxtec S EMC transit

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg
emi protection.svg

Transit for EMC, attached by welding.

For welding into precise apertures in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 66/67 according to IEC 60529

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec G EMC transit

Roxtec G EMC transit

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg
ip-ul nema.svg

Transit for EMC, attached by welding.

For welding in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 66/67 according to IEC 60529
  • IP 68
  • UL/NEMA 4,4X,12,13

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec GH EMC transit

Roxtec GH EMC transit

fire rated.svg
ip-ul nema.svg
emi protection.svg
gas-tight.svg

Transit for EMC, for bolting to even structures.

For bolting to steel or sandwich walls in EMC applications

Fire

  • E/EI rating according to EN 13501

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67 according to IEC 60529
  • IP 68

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec RS seal with SL RS

Roxtec RS seal with SL RS

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg

Penetration seal for a single cable or pipe.

Includes sleeve for welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E30
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve
  • Jet fire according to ISO 22899-1 and OTI 95634

Tightness

  • Gas: 2.67 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68
  • UL/NEMA 4,4X,12,13
Roxtec R transit with SL R

Roxtec R transit with SL R

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg

Round transit for sealing of multiple cables and pipes in a limited area.

Includes sleeve for welding

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 45545 E30
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68
Roxtec R EMC transit

Roxtec R EMC transit

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg
ip-ul nema.svg

Round transit for EMC, for area efficient sealing of multiple cables and pipes.

For use in existing sleeves in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • E/EI rating according to EN 13501
  • F/T rating according to UL 1479
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 68

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec R EMC transit with SL R

Roxtec R EMC transit with SL R

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg

Round EMC transit for welding when sealing multiple cable and pipes in a limited area.

Includes sleeve for welding in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec CF 8/32 EMC transit

Roxtec CF 8/32 EMC transit

ip-ul nema.svg
emi protection.svg

High cable density transit for electromagnetic shielding, with aluminum frame.

For EMC in high demand areas

Fire

  • N/A

Tightness

  • IP 66/67 according to IEC 60529
  • UL/NEMA 4,4X,12,13

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec CF 16 EMC transit

Roxtec CF 16 EMC transit

ip-ul nema.svg
emi protection.svg

Transit for electromagnetic shielding, with low profile frame.

For EMC where space is limited

Fire

  • N/A

Tightness

  • IP 66/67 according to IEC 60529
  • UL/NEMA 4,4X,12,13

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec WaveGuide Seal ES (Bolted)

Roxtec WaveGuide Seal ES (Bolted)

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg
emi protection.svg

Penetration seal for Electromagnetic shielding, for fiber optic cables.

For shielding and sealing of non-metallic fiber optic cables

Fire

  • A-CLASS according to IMO 2010 FTP Code

Tightness

  • Gas: 0.67 bar (catastrophic)
  • Water: 1 bar (catastrophic)
  • IP 66/67 according to IEC 60529

Supports

  • Electromagnetic shielding