Specifications
| Component family | Roxtec R frame |
| Material/group | Stainless steel |
| Packing space (mm) | 80 x 80 |
| External dimensions ØxD (mm) | 148 x 85 |
| Aperture dimension Ø (mm) | 127 - 129 |
| Weight (kg) | 1.1 |
| Art. No | R000001271021 |
Downloads
Downloads
The Roxtec R frame is round with a square packing space for multiple cables, pipes and modules. Compression is integrated in the frame. Allows installation around existing cables and pipes.
- To be used with corresponding Roxtec components to form a complete sealing solution
- Attachment by expansion in holes
- Sleeve accessory available
| Certifying authority | Rating | Division / Structure | Cable | Pipe | Type approval name | |
|---|---|---|---|---|---|---|
| Roxtec International AB | E fire EI fire | Concrete Concrete or Brickwork Lightweight concrete | Construction | Copper Steel | 0402-CPR-C500591 | |
| CSA | IP tightness UL/NEMA tightness | Other | Copper Steel | 1333944 | ||
| BV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | Bundle Copper Copper-Nickel Plastic Steel | 13965/E0 BV | |
| BV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Marine | 15027/E0 BV | ||
| USCG Certificate under renewal | H class fire | Steel | Armored Marine | 164.140/10/0 | ||
| IRS | A class fire | Steel | Marine | Bundle Copper Fiberglass Steel | 2022TAC104 | |
| VKF Switzerland | E fire EI fire | Concrete Lightweight concrete | Construction | Steel | 22787 | |
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Steel | 24-2519751-PDA | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Steel | 24-2519751-PDA-DUP | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Stainless steel Steel | Marine | 25-0212442-PDA | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Stainless steel Steel | Marine | 25-0212442-PDA-DUP | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | Bundle Copper Copper-Nickel Steel | 25-0251343-PDA | |
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | Bundle Copper Copper-Nickel Steel | 25-0251343-PDA-DUP | |
| Roxtec International AB | E fire EI fire | Concrete Concrete or Brickwork Lightweight concrete | Construction | Copper Steel | 2531-CPR-CXO10202 | |
| BV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Other | Marine | ABS Copper Copper-Nickel Fiberglass PB PE Plastic PP PVC PVDF Steel | 73351/A1 BV | |
| QinetiQ Certificate under renewal | A class fire Blastload Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | AS&P/BCC/30/13/002 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Construction Telecom | Conduit Steel | C-AJ-8309 | |
| Roxtec International AB | E fire EI fire | Concrete Concrete or Brickwork Lightweight concrete | Construction Telecom | Copper Steel | CE Declaration of Conformity (ETA-19/0584 | |
| Roxtec International AB | E fire EI fire | Concrete Concrete or Brickwork Lightweight concrete | Construction Telecom | Copper Steel | CE Declaration of Performance (DoP) ETA-19/0584 | |
| KRS Certificate under renewal | A class fire | Sandwich | Marine | CPH04189-FP001 | ||
| KRS Certificate under renewal | A class fire | Steel | Marine | CPH04189-FP002 | ||
| KRS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Steel | CPH04189-FP007 | ||
| Instytut Techniki Bodowlanej | EI fire | Concrete Concrete or Brickwork Lightweight concrete | Construction | Copper Steel | ETA-19/0584 | |
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 636 | ||
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 637 | ||
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 641 | ||
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 643 | ||
| CCS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Marine | GB23PTB00036_01 | ||
| CCS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Bundle Copper Copper-Nickel Steel | GB23PTB00036_02 | ||
| RINA | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | LAB484722CS/001 | ||
| RINA | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | LAB484722CS/002 | ||
| RINA | A class fire | Steel | Marine | LAB484722CS/003 | ||
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Other | Marine | Copper Fiberglass PB PE PE/ALU/PE Plastic PP PVC Steel | LR2386976SF | |
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Other | Marine | Copper Fiberglass PB PE PE/ALU/PE Plastic PP PVC Steel | LR2387043MB | |
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | GRP/FRP | Marine | LR2543793UKMB | ||
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | GRP/FRP | Marine | LR2543795UKMB | ||
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Marine | Bundle Copper Copper-Nickel Plastic Steel Titanium | LR26467444SFTC | |
| LR | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Marine | Bundle Steel Titanium | LR2668166SF | |
| DNV | A class fire Water tightness (catastrophic) | Aluminium | Copper Steel | MEDB000017T rev 2 | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Armored Marine Shielded | MEDB00001MS | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | MEDB00002SG | ||
| DNV | A class fire | Sandwich | Marine | MEDB000065Z | ||
| DNV | A class fire | Steel | Copper Copper-Nickel Steel | MEDB00006BG | ||
| DNV | A class fire | Sandwich | Copper Copper-Nickel PVC Steel Titanium | MEDB00008FD | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Copper Copper-Nickel Steel | MERB000017T | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | MERB00001MS | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | MERB00002SG | ||
| DNV | A class fire | Sandwich | Marine | MERB000065Z | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Copper Copper-Nickel Steel | MERB00006BG | ||
| DNV | A class fire | Sandwich | Copper Copper-Nickel PVC Steel Titanium | MERB00008FD | ||
| Myndigheten för samhällsskydd och beredskap | Blastload | Concrete Steel | Construction Other | Copper Steel | SRG7p-2026 | |
| ClassNK | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | TA251516E | ||
| ClassNK | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Bundle Copper Copper-Nickel Fiberglass Other Plastic Steel Titanium | TA26927E(R) | ||
| DNV | Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Aluminium Copper Copper-Nickel Plastic Steel | TAE000000X | ||
| DNV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Marine | TAF00000DH | ||
| DNV | H class fire | Sandwich | Marine | TAF0000147 | ||
| DNV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Steel | TAF00001NK | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Other | Marine | TAF00001SH | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Other | ABS Copper Fiberglass HDPE Other PB PE PE/ALU/PE Plastic PP PVC PVDF Steel | TAF00001SJ | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Conduit Steel | W-J-1300 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3248 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3249 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3253 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3255 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Construction | Conduit | W-J-8069 | |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | W-L-3360 | ||
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Other | W-L-3361 | ||
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | W-L-3365 | ||
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | W-L-3367 | ||
| Underwriters Laboratories Inc. | F fire T fire | Sandwich | Construction Telecom | Steel | W-N-8001 | |
| Underwriters Laboratories Inc. | F fire T fire | Concrete | Construction Other | XHEZ.C-AJ-3088 | ||
| Underwriters Laboratories Inc. | F fire T fire | XHJI7.R15556 | ||||
| Deutsches Institut für Bautechnik, DIBt | S fire | Casted Concrete Concrete or Brickwork Gypsum Lightweight concrete | Armored Fiber Other Shielded Unshielded | Z-19.15-1925 | ||
| Deutsches Institut für Bautechnik, DIBt | S fire | Concrete | Other | Copper Steel | Z-19.53-2347 | |
| Deutsches Institut für Bautechnik, DIBt | S fire | Brickwork Concrete Other | Other | Z-19.53-2635 |
Installation
Read more about the Roxtec sealing system and learn how to perform a correct transit installation on our installation pages.
Other Roxtec R frame variants
Galvanized mild steel
R 100 GALV
- Packing space (mm) 60 x 60
- External dimensions ØxD (mm) 115 x 85
- Aperture dimension Ø (mm) 100 - 102
- Weight (kg) 0.85
- Art. No R000001001018
R 125 GALV
- Packing space (mm) 80 x 80
- External dimensions ØxD (mm) 142 x 85
- Aperture dimension Ø (mm) 125 - 127
- Weight (kg) 1.1
- Art. No R000001251018
R 127 GALV
- Packing space (mm) 80 x 80
- External dimensions ØxD (mm) 148 x 85
- Aperture dimension Ø (mm) 127 - 129
- Weight (kg) 1.1
- Art. No R000001271018
R 150 GALV
- Packing space (mm) 90 x 90
- External dimensions ØxD (mm) 165 x 85
- Aperture dimension Ø (mm) 150 - 152
- Weight (kg) 1.6
- Art. No R000001501018
R 200 GALV
- Packing space (mm) 120 x 120
- External dimensions ØxD (mm) 215 x 85
- Aperture dimension Ø (mm) 200 - 202
- Weight (kg) 2.6
- Art. No R000002001018
Stainless steel
R 50 AISI316
- Packing space (mm) 30 x 30
- External dimensions ØxD (mm) 60 x 75
- Aperture dimension Ø (mm) 50 - 52
- Weight (kg) 0.21
- Art. No 5R00000012875
R 70 AISI316
- Packing space (mm) 40 x 40
- External dimensions ØxD (mm) 85 x 85
- Aperture dimension Ø (mm) 70 - 72
- Weight (kg) 0.45
- Art. No R000000701021
R 75 AISI316
- Packing space (mm) 40 x 40
- External dimensions ØxD (mm) 85 x 85
- Aperture dimension Ø (mm) 75 - 77
- Weight (kg) 0.51
- Art. No R000000751021
R 100 AISI316
- Packing space (mm) 60 x 60
- External dimensions ØxD (mm) 115 x 85
- Aperture dimension Ø (mm) 100 - 102
- Weight (kg) 0.83
- Art. No R000001001021
R 125 AISI316
- Packing space (mm) 80 x 80
- External dimensions ØxD (mm) 142 x 85
- Aperture dimension Ø (mm) 125 - 127
- Weight (kg) 1.07
- Art. No R000001251021
R 127 AISI316
- Packing space (mm) 80 x 80
- External dimensions ØxD (mm) 148 x 85
- Aperture dimension Ø (mm) 127 - 129
- Weight (kg) 1.1
- Art. No R000001271021
R 150 AISI316
- Packing space (mm) 90 x 90
- External dimensions ØxD (mm) 165 x 85
- Aperture dimension Ø (mm) 150 - 152
- Weight (kg) 1.6
- Art. No R000001501021
R 200 AISI316
- Packing space (mm) 120 x 120
- External dimensions ØxD (mm) 215 x 85
- Aperture dimension Ø (mm) 200 - 202
- Weight (kg) 2.6
- Art. No R000002001021