Brug udskriftsknappen på siden for at få et optimeret udskriftslayout.
Roxtec RS PE er en rund gennemføringstætning, som består af to dele med en tilpasningsbar kerne med aftagelige lag. Komprimering er indbygget i tætningen. Produktet beskytter mod ledningsbåret EMI. Tillader montering omkring et eksisterende kabel eller rør.
- Til ét kabel/rør
- Sleeve fås som tilbehør
| Certificeringsmyndighed | Normering | Division/Struktur | Kabler | Rør | Indtast godkendelsesnavn | |
|---|---|---|---|---|---|---|
| BV | A class fire F+WT Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Armored Marine Shielded Unshielded | ABS Bundle Copper Copper-Nickel Fiberglass HDPE Other PB PE PE/ALU/PE Plastic PP PVC Steel | 12509/E1 | |
| BV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Marine | 15027/E0 BV | ||
| ABS | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Stainless steel Steel | Marine | Bundle Fiberglass Steel Titanium | 24-0026230-PDA | |
| ABS | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Stainless steel Steel | Marine | Bundle Fiberglass Steel Titanium | 24-0026230-PDA-DUP | |
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Stainless steel Steel | Bundle Copper Copper-Nickel Fiberglass Steel | 25-0118234-PDA | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Fiberglass Steel | 25-0118234-PDA-DUP | ||
| ABS Certifikat under fornyelse | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | 25-0234779-PDA | ||
| ABS Certifikat under fornyelse | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | 25-0234779-PDA-DUP | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Bundle Copper Copper-Nickel Fiberglass Other Steel | 25-0278844-PDA | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Bundle Copper Copper-Nickel Fiberglass Other Steel | 25-0278844-PDA-DUP | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | 25-0389615-PDA | ||
| ABS | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | 25-0389615-PDA-DUP | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Construction Telecom | Conduit Steel | C-AJ-8309 | |
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 639 | ||
| Factory Mutual Approval | F fire T fire | Gypsum | Other | FM Fire Stop Design 644 | ||
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Marine | LR26387382SFTC | ||
| LR | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | Bundle Copper Copper-Nickel Fiberglass Steel Titanium | LR26387383SFTC | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Fiberglass Other Steel Titanium | MEDB0000128 | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | MEDB00002SD | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Bundle Copper Copper-Nickel Fiberglass Steel | MEDB00006GS | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Bundle Copper Copper-Nickel Fiberglass Other Steel Titanium | MERB0000128 | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Marine | MERB00002SD | ||
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium | Bundle Copper Copper-Nickel Fiberglass Steel Titanium | MERB00006GS | ||
| DNV | Gas tightness (catastrophic) Water tightness (catastrophic) | Aluminium Steel | All | Aluminium Copper Copper-Nickel Plastic Steel | TAE000000W | |
| DNV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Marine | TAF00000D8 | ||
| DNV | Gas tightness (catastrophic) H class fire Water tightness (catastrophic) | Steel | Fiberglass Other Steel | TAF00001NG | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Conduit Steel | W-J-1300 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3251 | ||
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | W-J-3256 | ||
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | W-L-3368 | ||
| Underwriters Laboratories Inc. | F fire T fire | XHJI7.R15556 |
Montering
Læs mere om Roxtec-tætningssystem, og få mere at vide om, hvordan du udfører en korrekt installation på vores installationssider.
Varianter
Til potentialudligning
RS 25 PE AISI316
- Til kabel/rør Ø (mm) 3.6 - 12
- Udvendige mål ØxD (mm) 32 x 43
- Hulstørrelse Ø (mm) 25 - 26
- Vægt (kg) 0.04
- Art.-nr. PRS0100251121
RS 31 PE AISI316
- Til kabel/rør Ø (mm) 4 - 17
- Udvendige mål ØxD (mm) 37 x 43
- Hulstørrelse Ø (mm) 31 - 32
- Vægt (kg) 0.06
- Art.-nr. PRS0100311121
RS 43 PE AISI316
- Til kabel/rør Ø (mm) 4 - 23
- Udvendige mål ØxD (mm) 53 x 86
- Hulstørrelse Ø (mm) 43 - 45
- Vægt (kg) 0.24
- Art.-nr. PRS0100431121
RS 50 PE AISI316
- Til kabel/rør Ø (mm) 8 - 30
- Udvendige mål ØxD (mm) 60 x 86
- Hulstørrelse Ø (mm) 50 - 52
- Vægt (kg) 0.32
- Art.-nr. PRS0100501121
RS 68 PE AISI316
- Til kabel/rør Ø (mm) 26 - 48
- Udvendige mål ØxD (mm) 78 x 86
- Hulstørrelse Ø (mm) 68 - 70
- Vægt (kg) 0.5
- Art.-nr. PRS0100681121
RS 75 PE AISI316
- Til kabel/rør Ø (mm) 24 - 54
- Udvendige mål ØxD (mm) 85 x 86
- Hulstørrelse Ø (mm) 75 - 77
- Vægt (kg) 0.58
- Art.-nr. PRS0100751121
RS 100 PE AISI316
- Til kabel/rør Ø (mm) 48 - 70
- Udvendige mål ØxD (mm) 110 x 86
- Hulstørrelse Ø (mm) 100 - 102
- Vægt (kg) 1.01
- Art.-nr. PRS0101001121
RS 125 PE AISI316
- Til kabel/rør Ø (mm) 66 - 98
- Udvendige mål ØxD (mm) 145 x 86
- Hulstørrelse Ø (mm) 125 - 127
- Vægt (kg) 1.57
- Art.-nr. PRS0101251121
RS 100 PE AISI316 WOC
- Til kabel/rør Ø (mm) 48 - 70
- Udvendige mål ØxD (mm) 110 x 86
- Hulstørrelse Ø (mm) 100 - 102
- Vægt (kg) 0.85
- Art.-nr. PRS0001001121
RS 125 PE AISI316 WOC
- Til kabel/rør Ø (mm) 66 - 98
- Udvendige mål ØxD (mm) 145 x 86
- Hulstørrelse Ø (mm) 125 - 127
- Vægt (kg) 1.23
- Art.-nr. PRS0001251121
RS 150 PE AISI316 WOC
- Til kabel/rør Ø (mm) 93 - 119
- Udvendige mål ØxD (mm) 170 x 86
- Hulstørrelse Ø (mm) 150 - 152
- Vægt (kg) 1.58
- Art.-nr. PRS0001501121