Shelters in the field host mission critical equipment and serve as hubs for communication between the base and the troops. Roxtec cable and pipe transits can be used in any harsh area for wall, floor and roof penetrations to ensure protection against threats from electronic warfare, shock-waves, extreme temperatures and wet conditions.

Why use Roxtec?

  • Watertight
  • EMI/EMP protection
  • Blast load protection
  • Shock-wave resistant
  • Temperature resistant

Superior simplicity

  • Easy and safe installation
  • One cut-out for dozens of pre-terminated cables
  • Flexibility for cables and pipes of different sizes
  • Built-in spare capacity for upgrades and retrofits
  • Customized solutions for specific requirements
Sealing solution options
Roxtec S EMC transit

Roxtec S EMC transit

fire rated.svg
watertight.svg
gas-tight.svg
ip-ul nema.svg
emi protection.svg

Transit for EMC, attached by welding.

For welding into precise apertures in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)
  • IP 66/67 according to IEC 60529

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec GH EMC transit

Roxtec GH EMC transit

fire rated.svg
ip-ul nema.svg
emi protection.svg
gas-tight.svg

Transit for EMC, for bolting to even structures.

For bolting to steel or sandwich walls in EMC applications

Fire

  • E/EI rating according to EN 13501

Tightness

  • Gas: 0.1 bar (catastrophic)
  • IP 66/67 according to IEC 60529
  • IP 68

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec R EMC transit with SL R

Roxtec R EMC transit with SL R

fire rated.svg
watertight.svg
gas-tight.svg
emi protection.svg

Round EMC transit for welding when sealing multiple cable and pipes in a limited area.

Includes sleeve for welding in EMC applications

Fire

  • A-CLASS according to IMO 2010 FTP Code
  • H-CLASS according to IMO 2010 FTP Code + HC fire load curve

Tightness

  • Gas: 2.5 bar (catastrophic)
  • Water: 4 bar (catastrophic)

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec CF 16 EMC transit

Roxtec CF 16 EMC transit

ip-ul nema.svg
emi protection.svg

Transit for electromagnetic shielding, with low profile frame.

For EMC where space is limited

Fire

  • N/A

Tightness

  • IP 66/67 according to IEC 60529
  • UL/NEMA 4,4X,12,13

Supports

  • Electromagnetic shielding
  • Potential equalization
Roxtec RS UG™ seal

Roxtec RS UGâ„¢ seal

watertight.svg
gas-tight.svg
ip-ul nema.svg

Round seal for single cables and pipes entering via foundations.

For single cables and pipes

Fire

  • N/A

Tightness

  • Gas: 0.3 bar (constant)
  • Water: 0.5 bar (constant)
  • IP 68